转自:June 9, 2017发表的 5-considerations-25g-vs-40g-ethernet-debate

我最近听到一些业界砖家说40G以太网已死,需要转到25/50/100G的技术演进上来,结论简单粗暴,误人不浅。为认清此问题,需要考虑以下五点:

1. 服务器上联还是交换机互联

第一点,明确我们说的是用于服务器上联还是交换机互联,到目前,25G网络只用于服务器上联,没见过交换机使用25G互联。甚至思科都没有25G光模块,惠普企业的25G光模块价格比40G/100G的还高。换句话说,现在只有脑子进水才会用25G做交换机互联,明年或许有变化,那是另外一回事。

2. 交换机

第二点,应该看看市面上的交换机,例如,思科的93180YC-EX,端口支持10G/25G,而价格与10G的老产品差不多,整个产品是向下兼容的。SFP28支持1G/10G/25G,QSFP28支持10G/25G/40G/50G/100G

3. 网卡

网卡也是重点。服务器刚开始有25G接口,intel的25G网卡XXV710刚刚出货,和40G XL710价格差不多,比10G的X710略高。自2016年,惠普的服务器也搭配了Mellanox的640SFP28网卡,比10G网卡更有性价比。思科的C系列 Rack-Mount服务器也开始支持25G网卡,价格介于10G的1225和40G的1385.

我认为当前的刀片服务器还没有25G接口,所有厂商都在研25G产品。思科的B系列UCS是目前仅有的支持40G接口的刀片服务器,价格比10G的产品贵40%,期待下一代25G产品价格能下降。

4. 线缆

5. 功耗和散热

选择25G的最后一个原因基于功耗和散热的考虑,按Mellanox 和Qlogic的说法,25G比40G更简单,功耗应该更低。然后,intel的产品710网卡不是这样,25G XXV(双口25GBase-CR-L)网卡典型功耗8.6W, 而10G X(双口10Gbase-SR)为4.3W,双口DAC为3.3W,40G XL(双口 40Gbase-CR4)为3.6W。然而,其他家的25G网卡的确比40G网卡(思科17W, intel的老网卡10W)功耗更低。

总结

总之,我也倾向数据中心选用支持25G的交换机,但是,这不是一个to be or not to be的选择,而是看需求,比如25G比40G可以传输更远。

我觉得交换机互联带宽更重要,在数据中心建设上,100G端口只比40G端口贵25%,但是带宽提高到250%,性价比凸显。

然而对于园区网和接入网,需要长距传输和低带宽,对于10G上行的扩容需求没有那么强烈,如果必须,现在可以选择40G。或许若干年后,25G上行会更便宜。

==============================================

下面是原文

==============================================

I’ve recently come across a number of comments from industry experts declaring that 40G Ethernet is dead — that it’s a given for organizations to jump on the 25/50/100G path. Those conclusions are simplistic and misleading. To really get at the heart of this question, organizations need to look at five critical factors.

1. Switch-to-Server or Switch-to-Switch?

The first consideration is whether you’re thinking of 25G for switch-to-server or switch-to-switch (or switch-to-blade switch). Right now, network vendors are positioning 25G only for switch-to-server. I don’t see any network vendor advertising 25G for switch-to-switch — Cisco doesn’t even offer a 25G fiber transceiver, and HPE has priced theirs higher than 40G and 100G transceivers! In other words, no one is talking about 25G for switch-to-switch links right now. It might be a different story in 2018; we’ll see.

2. Switch Options

The second place to focus your attention is on the switches. Most switches currently sold, like Cisco’s 93180YC-EX, support both 10G and 25G at a price matching older 10G products and with full backward compatibility — for example, each SFP28 port supports 1G, 10G or 25G, and each QSFP28 port supports 10G, 25G, 40G, 50G or 100G.

3. Server Network Interface Controllers

NICs are an important consideration. Servers are just beginning to see 25G. Intel recently began shipping their first 25G NIC (the XXV710), at about the same price as their equivalent 40G NIC (the XL710) and a bit more than their 10G adapters (the X710). Meanwhile, HPE has been selling a 25G Mellanox NIC since 2016 (the 640SFP28) with a price comparable to their 10G NICs. Cisco will introduce a 25G VIC for C-Series Rack-Mount Servers sometime later this year, priced between the 10G VIC-1225 and their current 40G VIC-1385.

I don’t believe any blade server does 25G today, but I’m sure all vendors are working on it. Cisco UCS B-Series is the only blade server to natively support 40G today, at about a 40 percent premium over 10G. When Cisco introduces 25G in its next-generation UCS B-Series products, I expect the price premium to drop.

4. Cabling

Another hardware angle that needs to be covered is cabling. It’s a big mistake to ignore cabling or assume it’s the same across vendors. Specifically, 25G twinax works best within a single rack with a top-of-rack switch and 1 and 2 meter cables. 25G with 3+ meter cables requires forward error correction (FEC), which adds ~250ns of one-way latency and may introduce vendor interop issues. If you’re adopting 25G, plan to densely pack compute into 10kVA–12kVA racks.

Here is a cabling comparison with market prices — there are some big swings in vendor pricing:

Length & Type 10G 25G 40G 100G
1 to 5 meters / Passive Twinax DAC 50–50–50–75 63−63−63-110 (Cisco)
122−122−122-196 (HPE)
175−175−175-316 (Intel)
3- and 5-meter cables not recommended
125–125–125–188 162–162–162–237
7 to 10 meters / Active Twinax DAC 180–180–180–205 N/A 550–550–550–625 N/A
1 to 30 meters / Active Optical 105–105–105–130 N/A 425–425–425–700 500–500–500–1,200
1 to 100 meters / SR Fiber Transceiver (for use with OM3/OM4 MMF LC cables)
Note: Each connection needs two transceivers and a MMF LC cable (20−20−20-100)
$478 (Cisco SFP-10G-SR-S)
$370 (Proline SFP-10G-SR)
$226 (Intel NIC E25GSFP28SR)
$1,112 (HPE NIC 845398-B21)
$911 (Proline)

No Cisco option currently
Note: 100 meters on OM4, 70 meters on OM3

$550 (Cisco QSFP-40G-SR-BD)

Note: This transceiver is now available from Proline, Arista and HPE.

N/A

Cisco has announced 100G-BiDi coming later this year, estimated at $800|

5. Power and Heat

A final consideration for adopting 25G is power and heat. Since 25G is simpler, it should use less power and produce less heat than 40G (a common claim from Mellanox and Qlogic). Curiously, Intel breaks that assumption – Intel’s XXV 25G adapter draws 8.6W, while their 10G and 40G adapters draw 3.3W and 3.4W respectively (dual ports, twinax cabling). Still, today’s 25G NICs do draw less power than other 40G NICs like Cisco’s (17W) and Intel’s older 40G NICs (10W).

And the Winner Is…
In conclusion, I agree that you should prefer 25G-capable switches for your data center, but it’s not a do-or-die decision. It is likely that when you do have a need for 25G (e.g., all-flash hyperconverged cluster or a high I/O NSX Edge cluster), you’ll probably deploy dedicated 25G switches because of the 25G distance limitations.

I think it’s probably more important that you think about switch-to-switch bandwidth. Within the data center, 100G connectivity now costs just 25 percent more than 40G, but provides 250 percent of the bandwidth. So, choosing data center switches with 40/100G QSFP28 ports is a safe bet.

Meanwhile, in campus and access networks with their long fiber runs and low bandwidth needs, there is much less pressure to move from 10G uplinks. If you must, 40G is available today. Perhaps in a few years, 25G uplinks will be a cheaper alternative.

还有一个回复

The move to 25G Server connections will happen when IT and Network Managers need more bandwidth at the top of the rack to the next layer of the network.

This isn’t really a migration to 25G at the server but a migration to 100GbE at the top of the rack. When are 40GbE uplinks not enough for the density within the rack?

25G was a snoozer when the IEEE ratified 100GbE standard 802.3bj. No networking vendor pursued 25G downlinks. And rightfully so… we already had something faster; 40GbE. Why would anyone want 25GbE?

Here’s another reason 25GbE links make sense: What is the most abundant slot connector in servers today? You are right if you answered PCIe Gen3 x8. How much PCIe bandwidth does that support? You are right again! ~ 56Gbps. So, match up 2-ports of 25GbE to a 56Gbps PCIe slot and you’ve got better efficiency from network to server architecture performance. Better utilization per slot.

25GbE switches are really 100GbE switches today. Eventually these 100GbE switches will move downstream. Think about what we typically call 10GbE switches today? Do they have 40GbE uplinks? Shouldn’t we consider them 40GbE switches?

25G vs 40G以太网之争的五点思考相关推荐

  1. 40G以太网光模块解决方案

    众所周知,目前通信网络对高速度.高带宽的需求不断增长,低速率升级至高速率是必然趋势.在这种大趋势背景下,40G成为了大多数企业网络升级10G网络的首选方案.本期文章,易天光通信(ETU-LINK)来跟 ...

  2. 由优劣语言之争引起的思考

    作者:邹溪源,长沙资深IT从业者,多年来从事.net企业级架构设计和软件开发,目前在长沙某互联网公司担任高级工程师. https://www.cnblogs.com/xiyuanMore/p/1034 ...

  3. 洪泰基金俞敏洪:创业24年,我的五点思考

    转载于: http://t.qianzhan.com/daka/detail/170516-941eadf5.html 题图:洪泰基金创始合伙人 俞敏洪先生 本文来自微信号投资人说(touzirens ...

  4. 蚂蚁金服,马已今服:循环放贷高杠杆,ABS(Asset-backed Securities)与巴塞尔协议...

    10月25日,马云在外滩金融峰会上发表一段长达21分钟的演讲,公开diss国内金融体系: "中国金融没有系统性风险,因为没有系统." "今天的银行延续的还是当铺思想,抵押 ...

  5. 光纤会在将来完全取代铜缆吗?

    光纤电缆和铜缆都可以为家庭和企业提供互联网连接服务.但是现在,光纤电缆似乎在需要更高速度的数据中心中越来越受欢迎,因为光纤电缆可以提供更大的带宽和更长的传输距离.但随着以太网供电(POE)技术的发展, ...

  6. 服务器网卡支持25G,如何使用网卡连接10G/25G/40G服务器与交换机?

    如何使用网卡连接10G/25G/40G服务器与交换机? 2020年03月25日  1983 网卡(NIC)是一种可为计算机或服务器提供网络连接的硬件组件,是任何网络都必不可少的基本部件,尤其是企业网 ...

  7. 千兆以太网和快速以太网有什么区别?

    以太网是一种计算机局域网的技术,主要用来连接多个网络系统实现局域网(LAN)的一种方式.市面上以太网类型繁多,其中快速以太网和千兆以太网是目前最为常见的.本文将为您详细对比快速以太网和千兆以太网,区分 ...

  8. 关于10G/40G/100G数据中心光纤布线知识

    随着人们对于数据中心的扩建与可扩展性要求的不断增大,如何实现数据中心从40G/100G向400G的平滑演进成为一个在问题,提升竞争力成为布线甚而设施必须实现可靠性.可管理性和灵活性.光纤连接解决方案可 ...

  9. 100G 50G 25G光通信模块

    企业和云级网络的数据中心中各种"G"比比皆是,是时候搞清楚他们的性能了. 云计算的兴起和数据中心的扩展推动着最新的以太网速度升级,而基于云技术的大数据也已然增加了运营商的工作负载. ...

最新文章

  1. mongodb 初学 意外 连接服务器异常(Connection refused)
  2. “从A到I”智慧数据中心上海论坛
  3. golang 关闭gc 并手动gc_Golang 大杀器之跟踪剖析 trace
  4. tipi 深入理解php内核 pdf_大牛的学习笔记-深入理解Linux内核(完整版)
  5. 可视化caffe模型结构及在线可视化
  6. python删除重复文字_python如何删除文件中重复的字段
  7. java调用c 返回值_推荐--Linux平台下Java调用C函数(补充关于String类型函数返回值)...
  8. php项目网页音乐播放器插件,10个免费开源的JS音乐播放器插件
  9. 好员工为什么离你而去
  10. 哥尼斯堡七桥问题用计算机,哥尼斯堡七桥问题解法真的解不出来?请尽快解答.急...
  11. AMD重新进入核心竞争领域
  12. 企业微信如何实现PC端扫码登录第三方网站
  13. php 标准规范,PHP PSR标准规范
  14. 王道P41 T23(单链表实现)
  15. 字符串数组的三种形式
  16. php在线留言,PHP在线提交留言直接发到邮箱
  17. 热导方程的Matlab数值解方法
  18. python 边读边写文件_python也可以边玩边学,试试做个字符画看看
  19. java随机生日,使用java根据出生日期怎么得到还有几天就生日了
  20. Python 爬取西刺可用代理IP,自带检测。

热门文章

  1. 做不下去了,就开心一下吧。
  2. MySQL索引优化实践
  3. python curses_python curses 使用
  4. 【调剂】华东交通大学信息工程学院2022年硕士研究生招生预调剂公告
  5. PLC简单梯形图(一)
  6. hijackthis日志祥解
  7. 【Beta阶段】第八次Scrum Meeting
  8. ./scripts/feeds install -a 报警告
  9. Robotstudio软件:机床上下料工作站机器人示教编程
  10. 为金融场景而生的数据类型:Numeric