联想服务器显示屏显示HDD2,UCS C系列安置服务器排除的HDD问题故障CLI命令
本文描述几个命令行界面(CLI)命令,以及其他排除故障技术,可帮助排除硬盘驱动器(HDD)问题故障。排除的HDD问题故障佳方法是使用LED, GUI、BIOS, LSI选项ROM/MegaRaid GUI和日志。然而,这些选项总是不是可用的。在这种情况下,您能使用CLI。
There are no specific requirements for this document.
This document is not restricted to specific software and hardware versions.
The information in this document was created from the devices in a specific lab environment.All of the devices used in this document started with a cleared (default) configuration.If your network is live, make sure that you understand the potential impact of any command.
Refer to Cisco Technical Tips Conventions for more information on document conventions.
Note:在本文列出的某些命令取决于,如果有一个LSI MegaRaid控制器,当不是1064/1068e LSI控制器支持所有。
输入显示PCI适配器命令为了查看产品名称。此示例显示一台LSI 1064e适配器。
ucs-c2xx-m1 /chassis #show pci-adapter
Slot Vendor ID Device ID SubVendor ID SubDevice ID Product Name
---- --------- --------- ------------ ------------ ------------------------
M 0x1000 0x0056 0x152d 0x896d Cisco LSI 1064E Mezzan...
输入显示hdd命令为了查看HDDs的状态。
ucs-c2xx-m1 /chassis #show hdd
Name Status
-------------------- --------------------
HDD_01_STATUS present
HDD_02_STATUS absent
HDD_03_STATUS absent
HDD_04_STATUS absent
输入显示虚拟驱动器命令为了查看虚拟驱动器的状况。因为不要求您关闭服务器和输入BIOS查看信息,此命令是有用的。
ucs-c210-m2/chassis #scope storageadapter SLOT-5
ucs-c210-m2/chassis/storageadapter #show virtual-drive
Virtual Drive Status Name Size RAID Level
-------------- ------------------ ---------------------- --------- ----------
0 Optimal 139236 MB RAID 1
1 Degraded 974652 MB RAID 5
输入显示物理驱动命令为了查看物理驱动的状况。
ucs-c210-m2 /chassis/storageadapter #show physical-drive
Predictive
Slot Failure Drive Coerced
Number Controller Status Manufacturer Model Count Firmware Size Type
------ ---------- ------ ------------ ----------- ---------- -------- --------- ----
0 SLOT-5
1 SLOT-5 online SEAGATE ST9146852SS 0 0005 139236 MB HDD
2 SLOT-5 online SEAGATE ST9146852SS 0 0005 139236 MB HDD
3 SLOT-5 online SEAGATE ST9146852SS 0 0005 139236 MB HDD
4 SLOT-5 online SEAGATE ST9146852SS 0 0005 139236 MB HDD
5 SLOT-5 online SEAGATE ST9146852SS 0 0005 139236 MB HDD
6 SLOT-5 online SEAGATE ST9146852SS 0 0005 139236 MB HDD
7 SLOT-5 online SEAGATE ST9146852SS 0 0005 139236 MB HDD
9 SLOT-5 online SEAGATE ST9146852SS 0 0005 139236 MB HDD
10 SLOT-5 online SEAGATE ST9146852SS 0 0005 139236 MB HDD
输入显示错误计数器命令为了查看可校正和无法修复的错误的数量。
ucs-c210-m2 /chassis/storageadapter #show error-counters
PCI Slot SLOT-5:
Memory Correctable Errors: 0
Memory Uncorrectable Errors: 0
输入显示HW设置命令为了查看RAID控制器配置。
ucs-c210-m2 /chassis/storageadapter #show hw-config
PCI Slot SLOT-5:
SAS Address 0: 500e004aaaaaaa3f
SAS Address 1: 0000000000000000
SAS Address 2: 0000000000000000
SAS Address 3: 0000000000000000
SAS Address 4: 0000000000000000
SAS Address 5: 0000000000000000
SAS Address 6: 0000000000000000
SAS Address 7: 0000000000000000
BBU Present: true
NVRAM Present: true
Serial Debugger Present: true
Memory Present: true
Flash Present: true
Memory Size: 512 MB
Cache Memory Size: 394 MB
Number of Backend Ports: 8
输入显示物理驱动计数命令为了查看HDDs的编号。
ucs-c210-m2 /chassis/storageadapter #show physical-drive-count
PCI Slot SLOT-5:
Physical Drive Count: 9
Critical Physical Drive Count: 0
Failed Physical Drive Count: 0
在不访问CLI情况下,您能查看技术支持文件(/tmp/tech_support)为了得到关于HDDs的状态的信息。这是摘自显示从智能平台管理接口的技术支持文件的一个部分(IPMI)传感器的HDDs :
Querying All IPMI Sensors:
Sensor Name | Reading | Unit | Status | LNR | LC | LNC | UNC | UC | UNR
HDD0_INFO | 0x0 | discrete | 0x2181 | na | na | na | na | na | na
HDD1_INFO | 0x0 | discrete | 0x2181 | na | na | na | na | na | na
HDD2_INFO | 0x0 | discrete | 0x2181 | na | na | na | na | na | na
HDD3_INFO | 0x0 | discrete | 0x2181 | na | na | na | na | na | na
HDD4_INFO | 0x0 | discrete | 0x2181 | na | na | na | na | na | na
HDD5_INFO | 0x0 | discrete | 0x2181 | na | na | na | na | na | na
HDD6_INFO | na | discrete | na | na | na | na | na | na | na
HDD7_INFO | na | discrete | na | na | na | na | na | na | na
这是摘自显示HDD状态的细分的技术支持文件的一个部分:
Bit[15:10] - Unused
Bit[9:8] - Fault
Bit[7:4] – LED Color
Bit[3:0] – LED State
Fault:
0x100 – On Line
0x200 - Degraded
LED Color:
0x10 – GREEN
0x20 – AMBER
0x40 – BLUE
0x80 – RED
LED State:
0x01 – OFF
0x02 – ON
0x04 – FAST BLINK
0x08 – SLOW BLINK
这是摘自显示HDD状态的技术支持文件的一个部分(与0x2181状态码) :
0x2181
Fault:
0x100 --- HDD is On Line
LED Color:
0x80 --- RED
LED State:
0x01 --- OFF
您有选项使用备用电池单元(BBU)以一些服务器部署。BBU是在断电期间,保护磁盘关于RAID控制器的写高速缓存数据72小时的一个智能备用电池单元。
此示例显示如何使用MegaCli为了检查BBU的状态:
bash$ sudo /opt/MegaRAID/MegaCli/MegaCli64 -AdpBbuCmd -a0 -NoLog
Password:
. . .
Battery Replacement required : Yes
. . .
Relative State of Charge: 99 %
Absolute State of charge: 76 %
. . .
Date of Manufacture: 11/08, 2008
Design Capacity: 700 mAh
Design Voltage: 3700 mV
Specification Info: 33
Serial Number: 243
Pack Stat Configuration: 0x6cb0
Manufacture Name: LSI113000G
Device Name: 2970700
Device Chemistry: LION
Battery FRU: N/A
此示例显示如何使用CLI为了检查BBU的状态:
ucs-c200-m2 /chassis/storageadapter #show bbu detail
Controller SLOT-7:
Battery Type: iBBU
Battery Present: true
Voltage: 4.023 V
Current: 0.000 A
Charge: 100%
Charging State: fully charged
Temperature: 34 degrees C
Voltage Low: false
Temperature High: false
Learn Cycle Requested: false
Learn Cycle Active: false
Learn Cycle Failed: false
Learn Cycle Timeout: false
I2C Errors Detected: false
Battery Replacement Required: true
Remaining Capacity Low: true
联想服务器显示屏显示HDD2,UCS C系列安置服务器排除的HDD问题故障CLI命令相关推荐
- 思科服务器型号m1414,Cisco UCS M 系列模块化服务器
特点和功能 当今的云应用需要有另一种更好的架构.计算功能需要从基础架构中抽离出来,才能提升密度,实现更轻松的扩展,并为管理.效率和性能提供完美的设计. UCS M 系列模块化服务器在设计上着眼于高度并 ...
- 联想服务器显示屏显示HDD2,联想电脑开机进入boot menu界面怎么办 带你快速解决一下...
1.按ESC键退出启动界面: 2.在当前界面选择硬盘HDD或其它启动设置回车确定后启动电脑. 联想笔记本开机出现BOOT MENU和APP MENU这很可能是三个原因:第一个原因:就是开机的时候无意中 ...
- 思科服务器管理口装系统,cisco思科统一计算系统UCS B系列刀片服务器推荐
如今,融合基础架构可谓大行其道,其能够整合系统,缩短部署时间,提高资源利用率并降低成本,得到了企业用户的广泛认可.作为融合基础架构的核心关键的计算平台,刀片基础架构则可以在机箱层面中实现很好的整合功能 ...
- 思科ucs-b系列服务器,思科统一计算系统UCS B系列刀片推荐
Cisco UCS B250 M2 Cisco UCS B250 M2 扩展内存刀片服务器有助于最大限度地提高要求最严格的虚拟化和大型数据集应用程序的性能和容量.这是一款全宽.双路的刀片服务器,其吞吐 ...
- 服务器不能显示中文,彻底解决delphi WebBroker服务器中文乱码 delphi WebBroker服务器不能显示中文网页 WebBroker中文显示乱码...
彻底解决delphi WebBroker服务器中文乱码 彻底解决WebBroker中文显示乱码 彻底解决delphi WebBroker服务器不能显示中文网页 这个问题被折腾惨啦! 网上一大堆,就没能 ...
- 服务器上显示叹号是什么意思,服务器上显示黄色叹号
服务器上显示黄色叹号 内容精选 换一换 当在服务器上成功部署SSL证书后,通过https://+域名的方式访问网站时,显示无法打开网站.可能原因一:未开启443端口可能原因二:配置文件未配置正确请根据 ...
- 魔兽世界服务器不显示角色信息,网易公告:部分服务器限制新角色创建功能
自<魔兽世界:大地的裂变>开放以来,玩家高涨的热情极大地鼓舞了我们,许多服务器均呈现一片繁荣景象.为了给大家更好的游戏体验,让所有的玩家都能拥有一个更加平衡和优异的游戏环境,我们在近期将根 ...
- 服务器上显示存储脱机,使存储空间直通服务器脱机以进行维护
使存储空间直通服务器脱机以进行维护 10/08/2018 本文内容 适用于: Windows server 2022.Windows server 2019 Windows Server 2016 本 ...
- mc服务器一直显示检测中,我的世界服务器一直显示登入中怎么办
许多玩家在玩我嘚世界嘚时候出现了,白.水碧.花紅,dnf新闻,raise father's ,. 情熱は海,服务器一直显示登入中嘚綪况,かない. 調和がとれて, you and I have beco ...
最新文章
- Java 中的关键字 final
- LeetCode.961-2N数组中N次重复的元素(N-Repeated Element in Size 2N Array)
- matlab中画花瓣,matlab画心,画玫瑰花,表白合集
- 计算机网络各层代表设备
- footer置底的几种方式
- 利用MySQL语句批量替换指定wordpress文章中的图片路径
- antd mysql_create-react-app使用antd按需加载的样式无效问题的解决
- 017-Centos7.6+CDH 6.2 安装和使用
- 南昌工程学院计算机考试题库和答案,南昌工程学院 语试题答案.doc
- python exec函数 自动代码规范_Python 开发编码规范
- 基于SSM的猫头鹰物流网站
- js获取后端传过来的数据
- Linux驱动基础知识(一)
- VC2005绿色编译器--命令行下编译C++代码
- 如何使用java实现一些常用的算法
- 向已知EXCEL模板写入数据并导出
- 智慧CAD手机精准看图隐私
- linux下安装配置dble--新手入门
- 房东家的网线不用账号和密码就能上网怎么设置路由器
- 《深度学习之美》第1章
热门文章
- net framework v4.8.0
- SFI立昌|KOYUELEC光与电子SHN系列方案应用
- java 输出验证码_输出 验证码图片
- 高考改卷中使用了大量计算机,中高考电脑阅卷原来是这样的!认真看多拿分!...
- 计算机科学与技术专业相关英语论文,计算机科学与技术专业 毕业论文 外文翻译中英文对照.doc...
- 单片机I/O的常用驱动与隔离电路的设计
- 【性能测试】系统常用监控- -CPU
- 完全二叉树叶子节点、度为1节点、度为2节点的个数
- 42个创意户外广告设计
- 机器人3D视觉引导技术,助力“中国制造2025”