有时候新接手维护服务器,或者在考虑当前服务器容灾备份机制时,首先得知道服务器到底是否存在RAID卡,是否已经配置RAID。最简单的方式就是重启服务器,然后根据提示查看相关信息。但很多情况下不能随便重启机器,那么我们可以通过特定的操作系统命令,或者查看相关日志得到该信息。注:此处讨论的是硬件RAID,不包括软件RAID

1、查看硬件是否支持RAID:

# lspci | grep RAID
02:00.0 RAID bus controller: Hewlett-Packard Company Smart Array Gen8 Controllers (rev 01)

  该命令查看了当前服务器是否存在RAID控制器,如果输出类似上面的信息,则表示硬件支持RAID,但实际是否配置以及如何配置还得进一步确定。

2、查看系统是否配置RAID

# dmesg |grep -i raid
dracut: rd_NO_DM: removing DM RAID activation
dracut: rd_NO_MD: removing MD RAID activation
hpsa 0000:02:00.0: RAID              device c2b3t0l0 added.
scsi 2:3:0:0: RAID              HP       P420i            3.42 PQ: 0 ANSI: 5

  如上所示,在系统日志中可以看到存在RAID设备,以及设备型号等信息。或者通过以下命令查看:

# cat /proc/scsi/scsi
Attached devices:
Host: scsi1 Channel: 00 Id: 00 Lun: 00
Vendor: hp       Model: DVDRAM GT80N     Rev: EA02
Type:   CD-ROM                           ANSI  SCSI revision: 05
Host: scsi2 Channel: 03 Id: 00 Lun: 00
Vendor: HP       Model: P420i            Rev: 3.42
Type:   RAID                             ANSI  SCSI revision: 05
Host: scsi2 Channel: 00 Id: 00 Lun: 00
Vendor: HP       Model: LOGICAL VOLUME   Rev: 3.42
Type:   Direct-Access                    ANSI  SCSI revision: 05
Host: scsi2 Channel: 00 Id: 00 Lun: 01
Vendor: HP       Model: LOGICAL VOLUME   Rev: 3.42
Type:   Direct-Access                    ANSI  SCSI revision: 05

  该命令显示了当前系统做完RAID后的磁盘个数,其中第二项显示为RAID磁盘,但没有显示RAID级别。

3、查看服务器RAID磁盘详情

  该部分内容通常无法通过系统自带命令或日志进行查询,需要使用RAID设备厂商提供的专用软件查看,此处以HP(惠普)服务器为例,进行演示。

  • 下载工具
    可通过官方网站下载工具 hpacucli-9.40-12.0.x86_64.rpm 点击此处

  • 安装工具

    # rpm -ivh hpacucli-9.40-12.0.x86_64.rpm
    
  • 工具使用

    3.1 RAID 磁盘概览

    # hpacucli ctrl all show configSmart Array P420i in Slot 0 (Embedded)    (sn: 50014380263D1E40)array A (SAS, Unused Space: 0  MB)logicaldrive 1 (279.4 GB, RAID 1, OK)physicaldrive 1I:2:1 (port 1I:box 2:bay 1, SAS, 300 GB, OK)physicaldrive 2I:2:5 (port 2I:box 2:bay 5, SAS, 300 GB, OK)
    array B (SAS, Unused Space: 0  MB)logicaldrive 2 (1.1 TB, RAID 0, OK)physicaldrive 1I:2:2 (port 1I:box 2:bay 2, SAS, 300 GB, OK)physicaldrive 1I:2:3 (port 1I:box 2:bay 3, SAS, 300 GB, OK)physicaldrive 2I:2:6 (port 2I:box 2:bay 6, SAS, 300 GB, OK)physicaldrive 2I:2:7 (port 2I:box 2:bay 7, SAS, 300 GB, OK)SEP (Vendor ID PMCSIERA, Model SRCv8x6G) 380 (WWID: 50014380263D1E4F)
    

    3.2 RAID磁盘详情

    # hpacucli ctrl all show config detail
    Smart Array P420i in Slot 0 (Embedded)Bus Interface: PCISlot: 0Serial Number: 50014380263D1E40Cache Serial Number: PBKUC0BRH4J3G6RAID 6 (ADG) Status: DisabledController Status: OKHardware Revision: BFirmware Version: 3.42Rebuild Priority: MediumExpand Priority: MediumSurface Scan Delay: 3 secsSurface Scan Mode: IdleQueue Depth: AutomaticMonitor and Performance Delay: 60  minElevator Sort: EnabledDegraded Performance Optimization: DisabledInconsistency Repair Policy: DisabledWait for Cache Room: DisabledSurface Analysis Inconsistency Notification: DisabledPost Prompt Timeout: 15 secsCache Board Present: TrueCache Status: OKCache Ratio: 10% Read / 90% WriteDrive Write Cache: DisabledTotal Cache Size: 1024 MBTotal Cache Memory Available: 816 MBNo-Battery Write Cache: DisabledCache Backup Power Source: CapacitorsBattery/Capacitor Count: 1Battery/Capacitor Status: OKSATA NCQ Supported: TrueSpare Activation Mode: Activate on drive failureController Temperature (C): 68Cache Module Temperature (C): 36Capacitor Temperature  (C): 28Array: AInterface Type: SASUnused Space: 0  MBStatus: OKArray Type: DataLogical Drive: 1Size: 279.4 GBFault Tolerance: 1Heads: 255Sectors Per Track: 32Cylinders: 65535Strip Size: 256 KBFull Stripe Size: 256 KBStatus: OKCaching:  EnabledUnique Identifier: 600508B1001C66AE8BFFC07021D139D8Disk Name: /dev/sdaMount Points: /boot 200 MB, / 279.2 GBOS Status: LOCKEDLogical Drive Label: A84609D850014380263D1E4034C5Mirror Group 0:physicaldrive 1I:2:1 (port 1I:box 2:bay 1, SAS, 300 GB, OK)Mirror Group 1:physicaldrive 2I:2:5 (port 2I:box 2:bay 5, SAS, 300 GB, OK)Drive Type: DataCaching Association: Nonephysicaldrive 1I:2:1Port: 1IBox: 2Bay: 1Status: OKDrive Type: Data DriveInterface Type: SASSize: 300 GBRotational Speed: 10000Firmware Revision: HPD6Serial Number: EB01PD21MUW01306Model: HP      EG0300FBDSPCurrent Temperature (C): 35Maximum Temperature (C): 42PHY Count: 2PHY Transfer Rate: 6.0Gbps, UnknownDrive Authentication Status: OKCarrier Application Version: 11Carrier Bootloader Version: 6physicaldrive 2I:2:5Port: 2IBox: 2Bay: 5Status: OKDrive Type: Data DriveInterface Type: SASSize: 300 GBRotational Speed: 10000Firmware Revision: HPD6Serial Number: EB01PCC1L8861251Model: HP      EG0300FBDSPCurrent Temperature (C): 34Maximum Temperature (C): 41PHY Count: 2PHY Transfer Rate: 6.0Gbps, UnknownDrive Authentication Status: OKCarrier Application Version: 11Carrier Bootloader Version: 6Array: BInterface Type: SASUnused Space: 0  MBStatus: OKArray Type: DataLogical Drive: 2Size: 1.1 TBFault Tolerance: 0Heads: 255Sectors Per Track: 32Cylinders: 65535Strip Size: 256 KBFull Stripe Size: 256 KBStatus: OKCaching:  EnabledUnique Identifier: 600508B1001CD6F301652A600B3E372ADisk Name: /dev/sdbMount Points: /mnt/u01 1.1 TBOS Status: LOCKEDLogical Drive Label: A846B29850014380263D1E403EF7Drive Type: DataCaching Association: Nonephysicaldrive 1I:2:2Port: 1IBox: 2Bay: 2Status: OKDrive Type: Data DriveInterface Type: SASSize: 300 GBRotational Speed: 10000Firmware Revision: HPD1Serial Number: ECA1PAC00GH11050Model: HP      EG0300FBDSPCurrent Temperature (C): 34Maximum Temperature (C): 44PHY Count: 2PHY Transfer Rate: 6.0Gbps, UnknownDrive Authentication Status: OKCarrier Application Version: 11Carrier Bootloader Version: 6physicaldrive 1I:2:3Port: 1IBox: 2Bay: 3Status: OKDrive Type: Data DriveInterface Type: SASSize: 300 GBRotational Speed: 10000Firmware Revision: HPD6Serial Number: EB01PD21MUYN1306Model: HP      EG0300FBDSPCurrent Temperature (C): 33Maximum Temperature (C): 45PHY Count: 2PHY Transfer Rate: 6.0Gbps, UnknownDrive Authentication Status: OKCarrier Application Version: 11Carrier Bootloader Version: 6physicaldrive 2I:2:6Port: 2IBox: 2Bay: 6Status: OKDrive Type: Data DriveInterface Type: SASSize: 300 GBRotational Speed: 10000Firmware Revision: HPD6Serial Number: EB01PD21MVFN1306Model: HP      EG0300FBDSPCurrent Temperature (C): 32Maximum Temperature (C): 43PHY Count: 2PHY Transfer Rate: 6.0Gbps, UnknownDrive Authentication Status: OKCarrier Application Version: 11Carrier Bootloader Version: 6physicaldrive 2I:2:7Port: 2IBox: 2Bay: 7Status: OKDrive Type: Data DriveInterface Type: SASSize: 300 GBRotational Speed: 10000Firmware Revision: HPD6Serial Number: EB01PD21MVF51306Model: HP      EG0300FBDSPCurrent Temperature (C): 31Maximum Temperature (C): 44PHY Count: 2PHY Transfer Rate: 6.0Gbps, UnknownDrive Authentication Status: OKCarrier Application Version: 11Carrier Bootloader Version: 6SEP (Vendor ID PMCSIERA, Model SRCv8x6G) 380Device Number: 380Firmware Version: RevBWWID: 50014380263D1E4FVendor ID: PMCSIERAModel: SRCv8x6G
    

  上图所示,服务器做了两个RAID,分别是Array A 和 Array B,前者由两块硬盘组建了RAID 1,后者由四块硬盘组建了RAID 0。

查看服务器是否配置RAID以及HP RAID详情相关推荐

  1. 服务器设置好后怎么显示,如何查看服务器已配置环境

    如何查看服务器已配置环境 内容精选 换一换 分析辅助软件是一款支持部署到多台服务器目标环境上,实现对整个业务集群的数据采集和优化的组件.已成功登录Java性能分析.待安装分析辅助软件的服务器已开启ss ...

  2. windows/linux查看服务器CPU配置命令

    基本概念: Intel的处理器分为至强Xeon.酷睿Core.赛扬Celeron.奔腾Pentium和凌动Atom5个系列. 英特尔® 酷睿™ .奔腾® .赛扬® 系列处理器都是面向笔记本或台式机的C ...

  3. 戴尔E14S服务器磁盘阵列配置实例(系统盘RAID 1,存储数据盘RAID 5)

    戴尔E14S服务器磁盘阵列配置实例 ●需求分析 现有一台戴尔E14S服务器需要进行硬盘划分以及Centos 7.6系统的安装.要求使用RAID 0的两块硬盘为系统盘,RAID 5的六块硬盘用来存储数据 ...

  4. 查看服务器的配置,系统,cpu等信息

    查看Linux服务器配置 目录 1.查看服务器的操作系统 ​编辑2.查看CPU信息  使用`lscpu`命令查看服务器CPU信息 3.查看Linux服务器CPU核数 4.查看内存信息 查看内存使用情况 ...

  5. 查看服务器CPU配置信息,转帖-CentOS查看CPU信息、位数、多核信息;查看服务器硬件信息...

    # uname -a Linux localhost.localdomain 2.6.18-164.el5PAE #1 SMP Thu Sep 3 04:10:44 EDT 2009 i686 i68 ...

  6. 查看服务器ip配置信息失败,U-Center 纳管戴尔的服务器报错“报错获取厂商信息失败,请确认IP、用户名、密码 、厂商、协议与配置文件是否正确”...

    1.先查询是否可以纳管该设备 2.检查配置 注意: 加前请先将该服务器通过增加设备的方式增加至U-Center中,此时U-Center将该服务器识别为PC,再通过增加服务器的方式将其识别为服务器. 输 ...

  7. 查看服务器Smart Array卡

    查看服务器的Smart Array: cciss0: HP Smart Array [root@oracle ~]# cat /proc/driver/cciss/cciss0 cciss0: HP ...

  8. 电脑查服务器型号,怎么在服务器的操作系统中查看服务器的型号

    一.DOS命令查看服务器的配置 1.查询CPU个数 cat /proc/cpuinfo | grep physical | sort -n | uniq | wc -l 2.查询服务器型号 dmide ...

  9. linux系统下查看服务器的型号等信息

    DOS命令bai查看服务器的配置 1.查询CPU个数 cat /proc/cpuinfo |du grep physical | sort -n | uniq | wc -l 2.查询服务器型号 dm ...

最新文章

  1. 《机电传动控制》学习笔记10-1
  2. 别把客户当傻子,延期交货得这么谈!
  3. wxWidgets:wxBusyCursor类用法
  4. jQuery使用CDN加速
  5. 第二章 API的理解和使用
  6. Vmware上安装RedHat Linux 7.3操作系统手册
  7. 【华为云技术分享】云图说 | 华为云AnyStack on BMS解决方案:助力线下虚拟化业务迁移上云
  8. oracle trace跟踪,浅析Oracle追踪工具SQL Trace的启用方式
  9. nginx和tomcat实现反向代理、负载均衡和session共享
  10. NER | 命名实体识别在QQ音乐上的应用
  11. MySQL配置与启动
  12. Atitit SOW项目工作说明书 目录 1. SOW工作说明书(Statement of Work,简称SOW) 1 2. 项目工作范围 1 3. 工作期限和工作量估计 1 4. 交付成果(源码
  13. macos备份文件服务器地址,mac电脑备份文件的最佳方法
  14. 三个路由器三个pc实现全网可达
  15. 2022年PMP考试的3A好考吗?
  16. Caffe--应用实践
  17. 通过设置路由器DMZ主机ip,却还是没法通过外网访问
  18. Chart.js使用(一)
  19. 神经网络物联网应用技术就业前景【欢迎补充】
  20. 【个人整理】省选知识点汇总

热门文章

  1. 基于条纹投影的结构光3D成像的研究分享
  2. Unity 欧拉角万向节锁的原理
  3. 全网最硬核 JVM TLAB 分析 4. TLAB 基本流程全分析
  4. 浅谈 ECMAScript 和 JavaScript
  5. 数据结构——栈和队列(上)
  6. 云以载道十年路,浪潮云海OS的未来已来
  7. spring boot对json 输入流数据拦截分析处理
  8. 自动驾驶代客泊车AVP功能介绍
  9. WPS演示 里有超链接的文字怎么改变格式
  10. wsl 2和vmware player不兼容